Acoustica ECO CHIP 30
A chipboard acoustic deck: moisture-resistant 18 mm P5 tongue-and-groove chipboard with a pre-bonded 12 mm high-performance resilient layer. Fit it direct to joists or as an overlay onto an existing subfloor.
55 dBAirborne DnT,w + Ctr (site test)
46 dBImpact L′nT,w (site test)
30 mmBoard thickness
1.44 m²Sheet · 600 × 2400 mm
Why ECO CHIP 30
- Ideal for general and new-build domestic separating floor upgrades
- Enhanced impact and airborne sound reduction
- Ready for the final floor finish, such as laminate, carpet and carpet tiles
- An economical system for conversion and new-build projects
Applications
Domestic dwellings, offices, hotels, conference centres, leisure centres, schools, restaurants and showrooms.
Tested build-up
- Acoustica ECO CHIP 30
- 200 mm deep timber joists
- Flat perimeter edging strip detail
- Resilient bars and 2 layers of 15 mm acoustic plasterboard
- 100 mm, 45 kg/m³ acoustic slab
Specification
| Product code | 0030 |
|---|---|
| Board | Moisture-resistant 18 mm P5 T&G chipboard with a pre-bonded 12 mm high-performance resilient layer |
| Use | Direct to joist, or as an overlay onto an existing subfloor |
| Sheet size | 30 × 600 × 2400 mm (1.44 m²) |
| Weight | 23.5 kg per sheet (two-person lift) |
| Site test data | Ref. DRUK/SIT/CCBSL/3015: airborne DnT,w + Ctr 55 dB, impact L′nT,w 46 dB, on the construction shown above |
| Method of compliance | PCT / PT (Scotland) |
| Ancillary products | Flat edging strip 50 lm × 75 mm × 5 mm · Approved adhesive 1 litre · Acoustic sealant 310 ml |
Installation at a glance
Before you start
- Keep boards dry and acclimatise for at least 24 hours
- Joists or subfloor must be flat, dry and free from debris
- Lay as a floating floor, with no mechanical fixings
- Direct-to-joist: lay across the joists, with all board ends on a joist
Laying
- Fit 5 mm perimeter edging strip to all walls, uncompressed
- Fully glue all T&G joints with the recommended adhesive
- Stagger board joints and seal any minor gaps with acoustic sealant
- Leave a 5 mm sealed gap at main entrance thresholds
After laying
- Keep off the floor for 24 hours while the adhesive cures
- PVA adhesive won’t cure below 5 °C
- Penetrations through the floor and ceiling must be detailed site by site
Need technical advice or a price?
Our team can help with specification and installation queries.
Call 07818 542495Email usInformation is correct to the best of our knowledge. Please contact us before starting works for the latest information and confirmation of the specification.