Timber & concrete floors · Low-profile overlay

Acoustica ECO CHIP 23

Big impact reduction, just 23 mm. 18 mm P5 tongue-and-groove chipboard bonded to a 5 mm recycled polyester fibre resilient layer. Laid over timber or concrete sub-decks on separating floors, before the final floor covering. Ideal for refurbishment.

⬇ Download data sheet (PDF)

23 mmTotal thickness
20 dBImpact improvement ΔLw*
1.44 m²Panel · 2400 × 600 mm
12.7 kg/m²Panel weight

Uses

  • Overlay for timber and concrete separating floors in flats and conversions
  • Refurbishment: only 23 mm thick, so minimal change to floor heights, thresholds and stairs
  • Any floor finish: ceramic tiles, timber flooring, carpet or vinyl go straight on top

Key benefits

  • Polyester resilient layer gives excellent impact reduction
  • Quick, easy installation with T&G edges
  • Low profile, with little impact on floor height
  • Resilient layer made from recycled polyester

System components

  • Acoustica ECO CHIP 23 panels
  • Perimeter flanking strip, isolating the floor from the walls

Specification

Panel18 mm P5 T&G chipboard bonded to 5 mm recycled polyester fibre resilient layer
Panel size2400 × 600 × 23 mm
Panel area · weight1.44 m² per panel · 18.3 kg per panel (12.7 kg/m²)
Panels per pallet70 panels (100.8 m²)
Pallet size · weight2400 × 1200 × 930 mm · 1330 kg
Suitable sub-decksIn-situ concrete, pre-cast concrete, block & beam, profiled metal deck, timber and metal web joisted floors
Robust DetailsE-FC-1, E-FC-2 and E-FS-1 (FFT 5)

Typical performance*

ConstructionAirborne DnT,w + CtrImpact L′nT,w
Concrete in-situ floor51 dB51 dB
Solid timber joisted floor49 dB57 dB
Profiled metal deck floor51 dB50 dB

*Typical figures from the manufacturer’s test data, indicative only. Impact improvement ΔLw measured on an in-situ concrete floor. Site results depend on the whole construction, flanking and workmanship, and pre-completion testing is required under Approved Document E. The data sheet shows each typical build-up in full.

Installation at a glance

Preparation

  • Level concrete floors to SR2 flatness
  • Timber subfloors must be sound and securely fixed
  • Fit the flanking strip around the room perimeter so the floor never touches the walls

Laying

  • Loose-lay panels resilient side down, staggering the joints
  • Glue all tongue-and-groove joints
  • Don’t screw or nail through the panels into the sub-deck

Finishing

  • Trim the flanking strip after the floor finish and skirting are fitted
  • Keep the skirting clear of the floor

Need technical advice or a price?

Our team can help with specification, installation and product queries.

Call 07818 542495Email us

The product and installation information is, to the best of our knowledge, correct. Please contact us before starting works for the latest information and confirmation of the specification.

© Copyright 2026 - Acoustica Sound Proofing